Ceramic Fiber Duplex-Heavy Build


CATALOG INDEX.....HOME .....ABOUT TEW&C ....
.
SALES REPS .....COLOR CODE CHART .....CORPORATE HQ.....OVERVIEW

• Heat Treatment
• Component Testing
• Steel and Aluminum
...Industry
• Metals Production
• Furnace Surveys
• Beaded Thermocouple
...Replacement
• Colored Tracers for Polarity
...Identification
• Impregnated Insulation and
...Jackets
• MICA/Glass Barrier Tape
• Stabilized Type K &

...Type E Conductors
• Twisted Pair
• Metal Coverings
• Tighter Than Special Limit
...Accuracy Tolerances
• Calibration Test Reports
• Continuous use up to
...2200F (1204C)
• Single exposure up to
...2400F (1316C)
Heavy Build Version
...of CEFIRSFTM
• Good Abrasion Resistance

Conductors:


Insulation:

Construction:

Jacket:

Operating Temperature:


Limits of Error:


Color Code:
Solid or stranded thermocouple wire per
ASTM E230 & ANSI MC96.1

Braided ceramic fiber

Parallel conductors

Braided ceramic fiber

+2200F (+1204C) continuous
+2400F (+1316C) single exposure

Conforms to ASTM E230, IEC 584
and ANSI MC 96.1

Supplied white without saturants or colored tracers


Conductor Size Insulation Thickness Jacket Thickness Outer Diameter Net Weight
AWG
12
14
16
16F*
18
18F*
20
20F*
22
22F*
24
24F*
(MM)
(2.06)
(1.63)
(1.29)
(1.47)
(1.02)
(1.22)
(0.81)
(0.97)
(0.64)
(0.76)
(0.51)
(0.61)
inches
.018
.018
.018
.018
.018
.018
.018
.018
.018
.018
.018
.018
(MM)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
inches
.018
.018
.018
.018
.018
.018
.018
.018
.018
.018
.018
.018
(MM)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
(.46)
inches
.153 x .270
.136 x .236
.123 x .210
.130 x .224
.112 x .188
.120 x .204
.104 x .172
.108 x .180
.097 x .158
.102 x .168
.092 x .148
.096 x .156
(MM)
(3.9 x 6.9)
(3.5 x 6.0)
(3.1 x 5.3)
(3.3 x 5.7)
(2.8 x 4.8)
(3.0 x 5.2)
(2.6 x 4.4)
(2.7 x 4.6)
(2.5 x 4.0)
(2.6 x 4.3)
(2.3 x 3.8)
(2.4 x 4.0)
LB/MF
50
33
24
26
18
19
14
15
12
13
9.5
9.9
(KG/KM)
(74)
(49)
(36)
(39)
(27)
(28)
(21)
(22)
(18)
(19)
(14)
(15)

MANY ITEMS AVAILABLE FROM STOCK WITHIN 24 HOURS
The products referenced above represent the most popular constructions. Other constructions can be manufactured
to meet individual specification and application requirements. Contact factory for additional information.

Table 1
Initial Calibration Tolerances Per ASTM E230 and ANSI MC96.1
Tolerance-Reference Junction 32F (0C)



Thermocouple Type


Temperature Range
F (C)


Grade
Designation
Standard Grade
Limits
F (C) whichever
is greater


Grade
Designation
Special Grade
Limits
F (C) whichever
is greater
Thermocouple Wire
T
J
E
K or N
T*
E*
K*
Extension Wire
TX
JX
EX
KX or NX

RX or SX
BX
BX

32 (0) to 700 (370)
32 (0) to 1400 (760)
32 (0) to 1600 (870)
32 (0) to 2300 (1260)
-328 (-200) to 32 (0)
-328 (-200) to 32 (0)
-328 (-200) to 32 (0)

32 (0) to 212 (100)
32 (0) to 400 (200)
32 (0) to 400 (200)
32 (0) to 400 (200)

32 (0) to 400 (200)
32 (0) to 212 (100)
32 (0) to 400 (200)

T
J
E
K or N
T
E
K

TX
JX
EX
KX or NX

RX or SX
BX***
BX ALLOY***

±1.8 (1) or ±0.75%
±4 (2.2) or ±0.75%
±3.1 (1.7) or ±0.50%
±4 (2.2) or ±0.75%
±1.8 (1) or ±1.5%
±3.1 (1.7) or ±1%
±4 (2.2) or ±2%

±1.8 (1)
±4 (2.2)
±3.1 (1.7)
±4 (2.2)

±9 (5)
±7.6 (4.2)
±6.7 (3.7)

TT
JJ
EE
KK or NN
TT
EE
KK

TTX
JJX
EEX
KKX or NNX

±0.9 (0.5) or 0.4%
±2 (1.1) or 0.4%
±1.8 (1) or 0.4%
±2 (1.1) or 0.4%
±0.9 (0.5) or 0.8%**
±1.8 (1) or 0.5%**
**

±0.9 (0.5)
±2 (1.1)
±1.8 (1)

±2 (1.1)

*

**
***
Thermocouple material is normally supplied to meet tolerances above 0C (32F). If material is required to meet
tolerances below 0C (32F), the purchase order must so state. Special selection of material is required.
Suggested initial calibration tolerance. Requirements should be discussed between purchaser and supplier.
Copper vs. copper can be used as an extension for Type B thermocouples if the transition is below 100C (212F).
Above 100C (212F), PCLW30-6 alloy should be used as the positive extension wire.


 
BACK. .CATALOG INDEX...HOME...ABOUT TEW&C...
SALES REPS
...COLOR CHART...CORPORATE HQ