Conductors:


Insulation:

Construction:

Jacket:

Operating Temperature:

Limits of Error:


Color Code:
Solid or stranded thermocouple wire per
ASTM E230 & ANSI MC96.1

Nylon polyamide resin

Parallel conductors

Nylon polyamide resin

-85F (-65C) to +250F (+121C) continuous

Conforms to ASTM E230, IEC 584
and ANSI MC 96.1

Conforms to ASTM E230 and ANSI MC
96.1 (International Color Codes Available)


Conductor Size Insulation Thickness Jacket Thickness Outer Diameter Net Weight
AWG
12
14
14F*
16
16F*
18
18F*
20
20F*
22
24
24F*
(MM)
(2.05)
(1.63)
(1.80)
(1.29)
(1.47)
(1.02)
(1.22)
(0.81)
(0.97)
(0.64)
(0.51)
(0.61)
inches
.008
.006
.006
.006
.006
.006
.006
.005
.005
.005
.005
.005
(MM)
(.20)
(.15)
(.15)
(.15)
(.15)
(.15)
(.15)
(.13)
(.13)
(.13)
(.13)
(.13)
inches
.008
.008
.008
.008
.008
.008
.008
.008
.008
.006
.006
.006
(MM)
(.20)
(.20)
(.20)
(.20)
(.20)
(.20)
(.20)
(.20)
(.20)
(.15)
(.15)
(.15)
inches
.113 x .210
.092 x .168
.100 x .184
.079 x .142
.086 x .156
.068 x .120
.074 x .132
.058 x .100
.062 x .108
.048 x .084
.042 x .072
.046 x .080
(MM)
(2.9 x 5.3)
(2.3 x 4.3)
(2.5 x 4.7)
(2.0 x 3.6)
(2.2 x 4.0)
(1.7 x 3.0)
(1.9 x 3.4)
(1.5 x 2.5)
(1.6 x 2.7)
(1.2 x 2.1)
(1.1 x 1.8)
(1.2 x 2.0)
LB/MF
43
29
31
18
21
12
13
7.8
8.9
5.0
3.3
3.7
(KG/KM)
(64)
(43)
(46)
(27)
(31)
(18)
(19)
(12)
(13)
(7.4)
(4.9)
(5.5)

MANY ITEMS AVAILABLE FROM STOCK WITHIN 24 HOURS
The products referenced above represent the most popular constructions. Other constructions can be manufactured
to meet individual specification and application requirements. Contact factory for additional information.

Table 1
Initial Calibration Tolerances Per ASTM E230 and ANSI MC96.1
Tolerance-Reference Junction 32F (0C)



Thermocouple Type


Temperature Range
F (C)


Grade
Designation
Standard Grade
Limits
F (C) whichever
is greater


Grade
Designation
Special Grade
Limits
F (C) whichever
is greater
Thermocouple Wire
T
J
E
K or N
T*
E*
K*
Extension Wire
TX
JX
EX
KX or NX

RX or SX
BX
BX

32 (0) to 700 (370)
32 (0) to 1400 (760)
32 (0) to 1600 (870)
32 (0) to 2300 (1260)
-328 (-200) to 32 (0)
-328 (-200) to 32 (0)
-328 (-200) to 32 (0)

32 (0) to 212 (100)
32 (0) to 400 (200)
32 (0) to 400 (200)
32 (0) to 400 (200)

32 (0) to 400 (200)
32 (0) to 212 (100)
32 (0) to 400 (200)

T
J
E
K or N
T
E
K

TX
JX
EX
KX or NX

RX or SX
BX***
BX ALLOY***

±1.8 (1) or ±0.75%
±4 (2.2) or ±0.75%
±3.1 (1.7) or ±0.50%
±4 (2.2) or ±0.75%
±1.8 (1) or ±1.5%
±3.1 (1.7) or ±1%
±4 (2.2) or ±2%

±1.8 (1)
±4 (2.2)
±3.1 (1.7)
±4 (2.2)

±9 (5)
±7.6 (4.2)
±6.7 (3.7)

TT
JJ
EE
KK or NN
TT
EE
KK

TTX
JJX
EEX
KKX or NNX

±0.9 (0.5) or 0.4%
±2 (1.1) or 0.4%
±1.8 (1) or 0.4%
±2 (1.1) or 0.4%
±0.9 (0.5) or 0.8%**
±1.8 (1) or 0.5%**
**

±0.9 (0.5)
±2 (1.1)
±1.8 (1)

±2 (1.1)

*

**
***
Thermocouple material is normally supplied to meet tolerances above 0C (32F). If material is required to meet
tolerances below 0C (32F), the purchase order must so state. Special selection of material is required.
Suggested initial calibration tolerance. Requirements should be discussed between purchaser and supplier.
Copper vs. copper can be used as an extension for Type B thermocouples if the transition is below 100C (212F).
Above 100C (212F), PCLW30-6 alloy should be used as the positive extension wire.


 
BACK..CATALOG INDEX...HOME...ABOUT TEW&C...